Originaldokumentationen är på engelska. Visa som Markdown (för AI/KB)
Description
The reset command resets the Accordion hardware system, returning it to its initial state. This includes resetting channels, clearing custom channel configurations, and reloading defaults.
Syntax
reset
This command has no options.
Output Format
Resetting..
Reset done, took 234.56 ms
What Gets Reset
- All channels return to default states
- Custom channel configurations are cleared
What is kept:
- Loaded modules remain loaded
- The connection remains active
- Alias/configuration files remain loaded
Timing
- Simple systems: 100–200 ms
- Complex systems: 200–500 ms
- Systems with many modules: 500–1000 ms
Use Cases
# Ensure a clean starting state before a test sequence
reset
wait --channel "READY" --value "1" --timeout 5000
Notes
- Requires an active connection (use
initfirst) - Does NOT disconnect from hardware, unload modules or clear alias files
- Blocking operation (waits for completion)
Error Handling
- Not connected: run
initfirst - Timeout: hardware not responding (may need a power cycle)