Module ESH10000533

M.2 PSU

Programmable DUT power with full telemetry — two independent channels, all controlled in software.

  • 2 independent channels, 0–20 V, 0–10 A, 60 W total (derated)
  • PMBus control via LTC3889 — configuration, protection and telemetry in software
  • Telemetry — voltage, current, power, input voltage/current, temperature
  • Protection — over/under-voltage, over-current, temperature, per channel
  • Remote sense per channel; per-channel calibration that persists across power cycles
Price on request
Description

ESH10000533 is a 2-channel programmable power module in M.2 form factor for test, verification and production. It provides two fully independent DC/DC outputs with PMBus control, built around the Linear Technology LTC3889. All configuration, control, telemetry and calibration happen in software — no manual adjustments are needed in normal operation.

Use cases
Powering M.2 DUTs during PCBA test, NPI and volume production.
Dynamic voltage control and margin testing during functional verification.
High-resolution current, voltage and power telemetry for diagnostics.
Automatic fault detection and protection handling in test sequences.
Technical information

Specifications, connections & manual

All technical material on the page — expand a section, or download the whole datasheet as a PDF.

Specifications

Electrical

Parameter Value Notes
Channels 2 (CH1, CH2) Fully independent
Max output power 60 W total Derated, total output power
Output voltage 0–20 V ±0.5 % of set-point
Output current 0–10 A
Current measurement ±(1 % rdg + 10 mA)
Controller Linear Technology LTC3889 (PMBus)

Protection

Protection Description
Overvoltage Warning and fault levels per channel
Undervoltage Warning and fault levels per channel
Overcurrent Warning and fault levels per channel
Temperature Over-/undertemperature, configurable response

Telemetry

Quantity Source
Output voltage READ_VOUT
Output current READ_IOUT
Output power READ_POUT
Input voltage READ_VIN
Input current READ_IIN
Temperature READ_TEMPERATURE_1 / 2

Manual

Each PMBus register is mapped to a named channel: {ModuleIndex}.ESH10000533.{Address}.{Channel} — e.g. 0.ESH10000533.0x4F.CH1.VOUT_COMMAND. Typically driven via Accordion API wrappers from C#, Python or TestStand.

Basic flow: set input-voltage thresholds (VIN_ON / VIN_OFF) → set output voltage, limits and protection → clear faults → enable (OPERATION / OUTPUT_ENABLE) → monitor telemetry → disable at end of step.

Calibration is per-channel (current-sense gain and temperature coefficient, input current), persistent across power cycles and applied automatically at startup.


Pinout

Pin Name Type Description
J2_1 VPSU_0 — Settable supply, channel 0
J2_2 VSENSE+_0 Input Remote sense +, channel 0
J2_3 VSENSE-_0 Input Remote sense −, channel 0
J2_4 GND — Common ground
J3_1 VPSU_1 — Settable supply, channel 1
J3_2 VSENSE+_1 Input Remote sense +, channel 1
J3_3 VSENSE-_1 Input Remote sense −, channel 1
J3_4 GND — Common ground