M.2 PSU
Programmable DUT power with full telemetry — two independent channels, all controlled in software.
- 2 independent channels, 0–20 V, 0–10 A, 60 W total (derated)
- PMBus control via LTC3889 — configuration, protection and telemetry in software
- Telemetry — voltage, current, power, input voltage/current, temperature
- Protection — over/under-voltage, over-current, temperature, per channel
- Remote sense per channel; per-channel calibration that persists across power cycles
ESH10000533 is a 2-channel programmable power module in M.2 form factor for test, verification and production. It provides two fully independent DC/DC outputs with PMBus control, built around the Linear Technology LTC3889. All configuration, control, telemetry and calibration happen in software — no manual adjustments are needed in normal operation.
Specifications, connections & manual
All technical material on the page — expand a section, or download the whole datasheet as a PDF.
Specifications
Electrical
| Parameter | Value | Notes |
|---|---|---|
| Channels | 2 (CH1, CH2) | Fully independent |
| Max output power | 60 W total | Derated, total output power |
| Output voltage | 0–20 V | ±0.5 % of set-point |
| Output current | 0–10 A | |
| Current measurement | ±(1 % rdg + 10 mA) | |
| Controller | Linear Technology LTC3889 (PMBus) |
Protection
| Protection | Description |
|---|---|
| Overvoltage | Warning and fault levels per channel |
| Undervoltage | Warning and fault levels per channel |
| Overcurrent | Warning and fault levels per channel |
| Temperature | Over-/undertemperature, configurable response |
Telemetry
| Quantity | Source |
|---|---|
| Output voltage | READ_VOUT |
| Output current | READ_IOUT |
| Output power | READ_POUT |
| Input voltage | READ_VIN |
| Input current | READ_IIN |
| Temperature | READ_TEMPERATURE_1 / 2 |
Manual
Each PMBus register is mapped to a named channel: {ModuleIndex}.ESH10000533.{Address}.{Channel} — e.g. 0.ESH10000533.0x4F.CH1.VOUT_COMMAND. Typically driven via Accordion API wrappers from C#, Python or TestStand.
Basic flow: set input-voltage thresholds (VIN_ON / VIN_OFF) → set output voltage, limits and protection → clear faults → enable (OPERATION / OUTPUT_ENABLE) → monitor telemetry → disable at end of step.
Calibration is per-channel (current-sense gain and temperature coefficient, input current), persistent across power cycles and applied automatically at startup.
Pinout
| Pin | Name | Type | Description |
|---|---|---|---|
| J2_1 | VPSU_0 | — | Settable supply, channel 0 |
| J2_2 | VSENSE+_0 | Input | Remote sense +, channel 0 |
| J2_3 | VSENSE-_0 | Input | Remote sense −, channel 0 |
| J2_4 | GND | — | Common ground |
| J3_1 | VPSU_1 | — | Settable supply, channel 1 |
| J3_2 | VSENSE+_1 | Input | Remote sense +, channel 1 |
| J3_3 | VSENSE-_1 | Input | Remote sense −, channel 1 |
| J3_4 | GND | — | Common ground |